Home
Products
Solutions
Applications
TechnologyAbout
Services
NewsContact
Solutions

Generation and storage sides,
one safety foundation

PV incidents come in exactly two forms: DC high voltage on the roof, and thermal runaway in the storage cabinet. Our two product lines address each, sharing LDSW standard-based communication, in-house SOC silicon and TinyML edge intelligence — so one customer gets one supplier, one interface and one safety ledger.

Four reference scenariosWireless, cabling-free retrofitThird-party verified data
HiSRSD module-level smart shutdown device
≤1 VArray-external voltage after shutdown — risk dismantled down to module level.
≥99.2%Communication success rate, third-party verified on a metro depot pilot.
300m+Effective coverage on complex sites; retrofit without cabling.
≥512Concurrent nodes per gateway, covering megawatt-scale rooftops.
Two product lines

Safety is not a point — it is a chain from generation to storage

Shutdown on the roof alone still leaves the storage cabinet flammable; suppression in the cabinet alone still leaves the roof live. A real closed loop addresses both ends.

HiSRSD · generation side

  • Protected against: DC shock hazard and string arcing, up to nearly 1,000 V
  • Core action: module-level shutdown within 25 s, array-external voltage ≤1 V
  • Triggers: power loss / command / fire interlock / edge AI diagnosis
  • Delivered as: device + gateway + cloud platform, wireless and cabling-free
  • Product details →

CS-500 · storage side

  • Protected against: lithium thermal runaway, flammable gas and in-cabinet deflagration
  • Core action: oxygen displacement + cryogenic cooling + suppression at onset
  • Triggers: combined temperature / smoke / characteristic-gas detection, two-parameter confirmation
  • Delivered as: storage + pressurisation + detection + spraying, skid-mounted
  • Product details →
Choose by scenario

Four project types, four different paths to deployment

Module-level shutdown means different things by segment: C&I cares about network scale and retrofit speed, public buildings about acceptance and fire interlock, residential about standardised delivery, overseas about standards alignment and no-outage installation.

C&I distributed PV

Large roof areas, dense strings, frequent servicing. The concerns are node scale, retrofit duration and O&M efficiency.

View solution →

Public buildings & rail

Schools, hospitals, metro depots. The concerns are fire acceptance criteria, emergency interlock and an auditable safety ledger.

View solution →

Residential PV

Small per-site capacity, many install points, long service radius. The concerns are installation speed, controllable cost and remote visibility.

View solution →

Overseas retrofit

Operating plants that cannot afford a long outage. The concerns are cabling-free, no-outage installation and local standards alignment.

View solution →
Evidence

The numbers are not ours to claim — they were issued by a third party

MetricResultBasis
Communication success rate≥ 99.2%20-unit pilot at a metro depot, East China; third-party acceptance
Voltage measurement error≤ ±0.2 VSame pilot, three months of continuous operation
Temperature measurement error≤ ±0.5°CSame pilot, three months of continuous operation
Continuous-operation data volume500,000+ recordsThree-month cumulative; data completeness does not vary with weather

Site characteristics: strong electromagnetic interference from traction return currents, rapid deployment required on existing canopy structures, continuous runs along the building facade. The site has been in continuous operation for over 12 months.

Next step

Give us your project conditions — we'll write a design, not a brochure

Roof area, installed capacity, inverter model, whether the plant is already operating, and your acceptance requirements. With those we produce a network design, node count calculation and payback estimate.

Request Sample

Validate project fit with a sample unit first.

Apply Now
Get Proposal

Tailored recommendations for your scenario.

Get Proposal
Business Inquiry

Need a quick answer? Talk to us directly.

Call Us